CHARACTERISTICS OF THE DE NOVO DATA CENTER

The De Novo data center is divided into two physical blocks in which the processes and metrics specified in the contract differ.

DC–1 is the only data center in Ukraine built on a modular basis.

Each module is a physically limited volume, which consists of separate shielded cameras connected to the engineering infrastructure.

DС–5 is intended for placement of the equipment in the common space.

The engine room consists of the unshielded cameras connected to the system of power supply of DC–1, zones of presence of telecom operators in DC–1 and the dispatching system. All other systems are their own.

COMPARISON OF DC–1 AND DC–5

 DC–1DC–5
Commissioning dateNovember 2010April 2018
Square2117 m21200 m2
Electrical capacitytotal 3050 kW
IT capacity1050 kW500 kW
Types of machine hallsS - 4 racks / 30 kW
L - 8 racks / 60 kW
H - 25 racks / 160 kW
2 halls with 36 racks each/ 115 kW
2 halls with 34 racks each / 115 kW
Machine halls shieldingThe resolution of NBU №243
The raised floor limit of load1500 kg800 kg
The rack limit of capacity≤ 15 kW power consumption≤ 10 kW the total value of the power supplies installed on one shoulder.
The microclimate of machine halls comply with ASHRAE
Telecommunications

2 inputs to the building, 2 telecom operator presence rooms

At least 15 telecom operators

External electricity supply2 inputs TM-4000/10 kVA with power supply from Nivki and Priorskaya substations
Power AssembliesАВВ MNSSchneider Electric
Diesel generators4 (N+1) Cummins
Fuel20 tons in main reservoirs and emergency tank
Uninterruptible power supplies2 rooms (N+1)
Batteries2 rooms (N+1)
Refrigeration System chiller-fancoil (N+1)
5 chillers Clivet
2 hydro accumulators
73 air conditioner STULZ
6 air conditioners STULZ
4 air conditioner APC
Precision air conditioners
4 x 4 (2) STULZ
ControlCitect SCADA software, Schneider Electric hardware
At least 29 000 controlled variables, at least 500 mimics
Access controlAPACS 3000, archive more than 200 days
The early fire detection systemSECURITON ASD 535FMST-FXV-44E
Fire suppressionFIKE, extinguishing agent HFC-227еаBGP Impulse-100-2 extinguishing agent HFC-125
Video surveillanceOver 120 cameras, archive more than 70 daysOver 50 cameras, archive more than 70 days
Support24 / 7 / 365 according to SLA
StaffAt least 6 workers per shift
Product DifferenceIndividual approach.
Additional equipment according to the technical task.
Implementation requires approvals
Products by the configurator.
Quick activation period

CABINET SPACE RENTAL

 Cabinet space rental in a shielded module Cabinet space rental in the collective engine roomRent ½ cabinets in the collective engine room
Rack typewidth up to 800 mm, depth up to 1200 mmwidth up to 800 mm, depth up to 1200 mmwidth up to 600 mm, depth up to 1100 (1200) mm
Rack heightUp to 48 UUp to 48 U20 U
Maximum power density≤ 15 kW / rack≤ 10 kW / rack for power supplies≤ 5 kW for power supplies
Power inputstwo independent
Topology of redundant precision cooling of IT equipment

universal: 

front → rear; 

bottom → top;

 front → top; 

front / bottom / rear → top

front → rear
Maximum rack weight1500 kg800 kg 
Communicationsdata center switching centers (2 pcs.) + intermodule communications (if necessary)data center switching centers (2 pcs.)

RENT A SECURE MODULE

 S-moduleL-module
Square14 m224 m2
Number of racks48
Power quota for IT equipment30 kW60 kW
Power density12 kW / rack
Ability to install enterprise racksyes
Power inputstwo independent
Topology of redundant precision cooling of IT equipmentuniversal: front → rear; bottom → top; front → top; front / bottom / rear → top
Load on the raised floor1500 kg (distributed), 500 kg (point)
Cable communicationsdata center switching centers (2 pcs.) + intermodule communications (if necessary)
Screeningin accordance with the requirements of the resolution of the NBU №243 from 04.07.2007
FirefightingAutonomous automatic gas, VESDA early detection system
Autonomous fire resistance60 minutes

GET AN OFFER

{{ getError('name') }}
{{ getError('company') }}
{{ getError('phone') }}
{{ getError('email') }}

De Novo Data Center offers a wide range of equipment placement services.

You can rent a rack or ½ rack in our Data Center.

For large companies and financial institutions, De Novo offers rental of individual shielded modules.

© 2008—2024 De Novo
6Lf8MgcaAAAAABG7vptCwS1Q5qOpAJNhvHkBRc_M
6Lcqv_QcAAAAAEfWcY6b8z_-3upRk2_J5SWPg027